Contact

ADDRESS:7&8 F, Bldg 8, No. 1699 Huishan Ave, Wuxi, Jiangsu, China
TEL:+86 510-85226288
FAX:+86 510-85224683
EMAL:info@farstar.com.cn

Products

Current Location:Home > Products

Neonatal Vital-Sign Monitor

Neonatal Vital-Sign Monitor
  • Name:Neonatal Vital-Sign Monitor
  • Time:2017/12/6 19:43:40
  • Clicks:
  • Price:Non pricing

Info

Product Features

7.5"Touchscreen with High Resolution

Neonatal Non-Invasive Blood Pressure [135mmHg] Excess-Pressure Protection.

Adjustable Neonatal Breath Pause Alarm Time (15 - 20 s)

Monitor Chart Trends and Reviews Up to 72 hours.

Data Recoverable and Charts Can be Replayed.

Oxygen Level Can be Monitored Seperately with Functions of Setting High and Low Limits of Oxygen Levels.

 Data Deposits and Review Functions Enable Caretakers for Further Examination.

Light and Portable for External Record and Connection to Central Networks

DC/AC Applicable with Internal Batteries for Up to 1.5 h Independent Power Supply.

Noncontact Breathing Head Mask Is Tailored and Designed for Newborns



Hear-Rate Modes
Lead Input:3/5 (3 for most cases)
3-Lead Mode:Ⅰ、Ⅱ、Ⅲ
5-Lead Mode:Ⅰ、Ⅱ、Ⅲ、AVR、AVL、AVF、V
Gain:2.5mm/mV,5.0 mm/mV,10 mm/mV,
20 mm/mV
Wave Speed:12.5mm/s,25 mm/s,50 mm/s,
Accuracy:±2% or ±1bpm
Resolution:1bpm
Leakage Current:<10μA
Protection:Separation Tolerance 4000V,50/60Hz voltage with anti-tremor protectin
Electrocardio Tabs:1mV±5%
Test Range:24~280bpm(b/min)
Alarm Range:100~180bpm(b/min)
ST Interval Analysis:Yes
Arrhythmia:Yes
Arrhythmia Alarm/Review:Yes

Alarm:multi-angle sound & light alarms with repetitions


Blood O2 Saturation Specification

Test Range:0~100%

Resolution:1%
Accuracy:80~100%±2%
0%~79% nondescriptable
Alarm Range:0~100% continuous
Pulse Rate:measurement and alarm range 30~250bpm
Resolution:1bpm
Accuracy:±2bpm
Alarm:multi-angle sound & light 

Breathe Mode
Mode:RA-LL impedence
Test Range:0~120rpm
Resolution:1rpm
Accuracy:±2rpm
Asphyxiation Detection and Alarm:15~20 s (adjustable by seconds)

Blood Pressure Type

Measurement Method: 

automatic oscillation 

Work Mode: manual/automatic/continuous

Auto-Measure Time:

1~960 min (adjustable)

Measurement Unit:mmHg/KPa

Type of measurement: 

systolic pressure / diastolic pressure / mean pressure

Measurement Range:

systolic:30~130mmHg

diastolic:10~100mmHg
mean:17~110mmHg
over-pressure protection:135 mmHg
Resolution:1 mmHg
For Continuous Adjustment

Body Temperature Mode
Test Range:0~50℃
Resolution:0.1℃
Accuracy:±0.1℃
Alarm Range:>37℃ or <36℃
Channel Number:Single

O2 Concentration Mode
Test & Alarm Range:21%~100%
Single Adjustment Interval:1%
Measurement Error:±5%
Update Time:6秒钟
Alarm Pause:1分

Standard Configuration Settings
3-Lead Heart Rate, Breathing, Non-invasive Blood Pressure, Blood Oxygen Saturation, Pulse, Single Body Temperature, Oxygen Concentration, Neonatal Oxygen Inhalation Hood.

Optional Settings
Recorder, CCTV Network System, Equipment Frame


ADDRESS:7&8 F, Bldg 8, No. 1699 Huishan Ave, Wuxi, Jiangsu, China
TEL:+86 510-85226288     FAX:+86 510-85224683      EMAL:info@farstar.com.cn